The reliability tests for this type of inductor are divided into environmental tests and physical tests. Environmental tests focus on the inductor's temperature resistance, humidity resistance, thermal shock resistance, etc.; physical tests mainly evaluate the inductor's strength, solderability, reflow soldering performance, drop resistance, impact resistance, etc.
I. Environmental Tests for Inductor ReliabilityMIL-STD-202G Method 108A High-Temperature Storage Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
Temperature: 85±2℃
Time: 96±2 hours
Samples shall be placed at room temperature for 1 hour and must be tested within no more than 2 hours.
IEC 68-2-1A 6.1 6.2 Low-Temperature Storage Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
Temperature: -25±2℃
Time: 96±2 hours
Samples shall be placed at room temperature for 1 hour and must be tested within no more than 2 hours.
MIL-STD-202G Method 103B Humidity Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
- Samples must first be dried at 40±5℃ for 24 hours;
- Test after drying;
- Exposure: Temperature: 40±2℃, Humidity: 93±3% RH, Time: 96±2 hours;
- Test in the test chamber after exposure;
- Samples shall be placed at room temperature for 1 hour and must be tested within no more than 2 hours.
MIL-STD-202G Method 107G Thermal Shock Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
Expose to -40℃ for T minutes, then shock to 125℃ for T minutes as one cycle, with a total of 20 cycles.
II. Physical Tests for Inductor ReliabilityMIL-STD-202G Method 208H IPC-J-STD-002B Solderability TestSolder coverage: The terminals must have more than 95% solder coverage.
- Immerse the terminals in flux and then in a 245±5℃ solder bath for 5 seconds;
- Solder: Sn(63)/Pb(37);
- Flux: Rosin flux.
IPC J-STD-020B Reflow Soldering Test
- No obvious appearance defects;
- Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%;
- DC resistance change does not exceed 10%;
- Go through the reflow soldering curve (see next page) three times;
- Peak temperature: 245±5℃.
MIL-STD-202G Method 201A Vibration Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
Vibrate along X, Y, Z directions with a frequency of 10-55Hz and an amplitude of 0.75mm for 2 hours each (total 6 hours).
MIL-STD-202G Method 203C Drop Test
- No obvious appearance defects; 2. Inductance change does not exceed 10%;
- Quality factor change does not exceed 30%; 4. DC resistance change does not exceed 10%;
Drop the packaged product from a height of 1 meter onto the test board, impacting 1 corner, 1 edge, and 2 faces.
JIS C 5321: 1997 Terminal Strength TestDefinition: A: Welded terminal cross-sectional area A≤8mm², thrust ≥5N;Time: 30 seconds; 8mm²≤20mm², thrust ≥10N;Time: 10 seconds; 20mm², thrust ≥20N;Time: 10 seconds;Bending test: After soldering the product to the PCB, the terminals shall not loosen after thrust test and bending test. Bend the PCB centrally to a deflection of 2mm.
IEC 68-2-45: 1993 Solvent Resistance TestNo appearance damage or marking damage. Immerse in IPA solvent for 5±0.5 minutes, dry at room temperature for 5 minutes, then wipe 10 times.
—— Integrated Inductor ——Integrated inductors also undergo both environmental tests and physical tests. Environmental tests mainly assess temperature resistance, humidity resistance, thermal shock resistance, etc.; physical tests focus on strength, solderability, reflow soldering performance, drop resistance, impact resistance, etc. So what are the standards for integrated inductors?
-
Environmental Tests for Integrated Inductor ReliabilityHigh-Temperature Storage Test: No obvious appearance defects; inductance change does not exceed 10%; quality factor change does not exceed 30%; DC resistance change does not exceed 10%; Temperature: 85±2℃; Time: Samples shall be placed at room temperature for 1 hour and must be tested within no more than 2 hours.Picture
-
Physical Tests for Integrated Inductor Reliability(1) Solderability Test: Terminals must have more than 95% solder coverage: Immerse the terminals in flux and then in a 245±5℃ solder bath for 5 seconds; use rosin flux.(2) Reflow Soldering Test: No obvious appearance defects; inductance change does not exceed 10%; quality factor change does not exceed 30%; DC resistance change does not exceed 10%.(3) Vibration Test: No obvious appearance defects; inductance change does not exceed 10%; quality factor change does not exceed 30%; DC resistance change does not exceed 10%; vibrate along X, Y, Z directions with a frequency of 10-55Hz and an amplitude of 0.75mm for 2 hours each (total 6 hours).(4) Drop Test: No obvious appearance defects; inductance change does not exceed 10%; quality factor change does not exceed 30%; DC resistance change does not exceed 10%.
-
Bending TestSolder the integrated inductor to the PCB; after thrust test and bending test, the terminals shall not loosen. Bend the PCB centrally to a deflection of 2mm.
-
Solvent Resistance Test for Integrated InductorsUnder the condition of no appearance damage or marking damage, immerse the integrated inductor in IPA solvent for 5±0.5 minutes, dry at room temperature for 5 minutes, then wipe 10 times.